Hill-Rom P1900 TotalCare Hospital Bed

$2,950.00$3,250.00

SKU: N/A Categories: ,

(not recommended for home use)

Clear
FacebookTwitterGoogle PlusPinterestTumblrLinkedin

Description

The Hill-Rom® TotalCare® Model P1900 bed provides maximum comfort to patients in critical condition and greatly reduces stain to caregivers.  This bed features both hydraulic and manual controls which the caregiver can easily transition the patient surface into numerous positions from either side using Point-Of-Care™ siderail controls and HandsFree™ foot controls. The hydraulic movements provide for smoother bed positioning for patients.  The bed comes standard with a Short Stay Surface to provide patient pressure reduction or optional Treatment Air Surface that provides continuous full-body pressure relief management through automatic adjustments in air system to accommodate changes in weight distribution.   Furthermore, TotalCare® offers many optional full interaction caregiver controls through a Graphical Control Interface (GCI) which operate optional functions such as bed exit alarm, integrated scale functions, foot elevation and air mattress system.   In addition, this bed offers three chair positions (chair, chair egress and recliner) and FlexAfoot™ retractable foot mechanism to extend or retract foot section.   Also, battery backup is available when there is a power loss to temporarily operate the bed positioning functions.

Due to its versatility, numerous features, and ease of use in emergency situations, this bed is ideal for acute patient care, medical/surgical care, post anesthesia care, and Intensive Care Units.

Note: Due to the complexity and service requirements of the TotalCare® bed, this bed is not recommended to be used in residential settings.

Additional Information

Allowable weight

up to 500 lb

Configuration

Standard Configuration, non-scale, With Scale

Manufacturer

Hill-Rom

Model Number

P1900

Warranty

(1)-year parts only

Reviews

There are no reviews yet.

Be the first to review “Hill-Rom P1900 TotalCare Hospital Bed”

This site uses Akismet to reduce spam. Learn how your comment data is processed.

  • Short Stay Surface – Modular, three-layered foam mattress with a viscoelastic core and foam-side bolsters. Mattress size: 35”w x 84”l (89cm x 213.4 cm)
  • Step deck
  • Hydraulically operated for smoother bed positioning
  • Shearless Pivot™ Patient Position Mechanism
  • FlexAfoot™ Retractable Foot Control
  • FullChair™ Patient Position Control
  • FullChair™ Patient Egress Position Control
  • Tuck-away dual head and intermediate siderails with OneStep™ Siderail release mechanism
  • Point-of-Care™ Siderail controls – Caregiver controls on outside of siderails for bed up/down, head up/down, knee up/down, chair in/out, bed flat, Trendelenburg/Reverse Trend, Foot up/down, and lockouts for bed system articulating functions.
  • Point-of-Care™ Brake and Steer System
  • FlexAfoot™ Retractable Foot Mechanism – to extend or retract foot section. Foot section can be retracted 12” (30.5 cm)
  • HandsFree™ Emergency CPR/Trendelenburg Release Mechanism
  • WallGuardä bumper system
  • Line-of-Site™ Head Angle Indicator
  • Line-of-Site™ Trendelenburg Indicator
  • Point-of-Care™ Hi/Lo bed controls on head siderails
  • Removable Headboard (Can be used for emergency CPR)
  • Removable Footboard
  • Equipment sockets
  • Safety and Information indicators such as “Brake Not Set”, Chair Position, “Remove Footboard”, “Unplugged AC”, Optional Battery Power, and “Service Required”.
  • Integrated patient position locator
  • IV Sockets 0 bed come with six standard IV sockets – 4 are located at head end and two are located at the corners of the foot end.
  • Drainage bag holders
  • Patient Restraint Interface – facilitates vest, wrist, waist and ankle restraints
  • Standard 5” (12.7 cm) Tente® casters
  • Hospital grade power plug
Patient Surface Characteristics:
  • Maximum Height: 74” (188 cm)
  • Maximum Width: 36” (91.4 cm)
  • Maximum Weight: 500 lbs (226.8 kg)*
  • Minimum Weight: 70 lbs (32.0 kg)
*Includes mattress, IV pumps, poles, bags, etc.  Scale accuracy may be diminished if patient weight exceeds 400 lbs. (181.4kg).  Mattress interface pressure performance may be diminished if patient weight exceeds 300 lbs (136.1 kg).
  • Weighing capacity: 400 lbs (181.4 kg)
  • Maximum Safe Working Load: 500 lbs. (226.8 kg)
Bed Height:
  • Low position (minimum height): 17.5” (44.5 cm)
  • High position (maximum height): 36.5” (92.7 cm)*
*Add 17.75” (45.09 cm) to max bed height with siderails up. Sleep Surface:
  • Maximum width (siderails down): 36” (91 cm)
  • Maximum width (siderails up): 40” (102 cm)
  • Total length: 84” (213 cm)
  • Bed total length with roller bumpers: 93.5” (237.5 cm)
  • Retracted length: 81.5” (207.01 cm)
  • Foot retraction: 12” (30.5 cm)
  • Mattress support width: 35” (89 cm)
  • Mattress support length: 84” (213.4 cm)
Head and Footboard Height:
  • Maximum headboard height: 54.25” (137.80 cm)
  • Maximum footboard height: 54.25” (137.80 cm)
Siderail Height:
  • Maximum height: 54.25” (137.80 cm)
Bed Clearance:
  • Minimum under-bed clearance: 4.75” (12.1 cm)
Hi-Lo Range:
  • Total Hi-Lo range: 19” (48.26 cm)
Bed Articulations:
  • Max head of bed elevation: 0° – 75°
  • Max knee elevation: 0° – 20°
  • Max automatic contour elevation: 0° – 15°
  • Automatic contour down: 28°
  • Automatic contour (knee): 10°
  • Foot: 85° Down
  • Preliminary Tilt Table: 20°
  • Articulating Deck: 32.5” x 84” (82.6 cm x 213.4 cm)
  • Maximum Trendelenburg/Reverse: 15°/ 15°
  • Caregiver Graphical Control Interface (GCI) control to operate additional optional features such as Bed Exit alarm, integrated scale functions, foot elevation, preliminary tilt and air treatment surface system (Max-Inflate and Heel Suspension modes).
  • Treatment surface – Air mattress for full-body pressure relief management through automatic adjustments in air system to accommodate changes in weight distribution.
  • Nurse Call and Entertainment controls
  • Patient positioning controls on inboard side of the intermediate siderails (patient can control head up/down, knee up/down, nurse call, room light/read light and entertainment controls)
  • Transport handles
  • Permanent IV poles at headend of bed
  • Removable IV pole
  • Battery Power backup (Manual Control Option)
  • Alarm Silence Control in the event of excessive air loss, pressure changes, or air system failure, the optional Treatment Surface will initiate continuous alarm.
  • Fluoroscopy Option
  • Patient restraint straps
  • X-Ray Cassette Sleeve – Large 20” x 17” – 50.8 cm x 43.2 cm / Small 19” x 17” – 48.3cm x 43.2cm)
  • Upgraded 5” (12.7 cm) Dual Design Wheel Casters
  • Accessory AC (120V) receptacle
  • Vertical Oxygen Tank Holder
  • Transducer holder
  • Transport Shelf/Charting table
  • Seat belt
  • Fracture Frame Adapter Brackets